Int. J. Life. Sci. Scienti. Res., 2(2): 173-182, March 2016
Air Pollution Tolerance Index of Some Trees Species from the Industrial area of Tarapur
*Nitesh Joshi1, Ambika Joshi2 and Bharati Bist1,
1Department of Botany, Rizvi Collegeof Arts, Science and Commerce, Bandra West, Maharashtra, India
2Department of Botany, Jai hind College, Churchgate, Maharashtra, India
ABSTRACT: To evaluate the susceptibility of plants growing in the industrial area of Tarapur, Maharashtra, Air pollution tolerance index (APTI) was determined for 30 plants species by calculating Ascorbic acid content, Leaf-extract pH, Total chlorophyll content and Relative water content and computing together in a formula. The result showed the order of tolerant species as Putranjiva roxburghii >Mangifera indica >Ficus racemosa >Ficus hispida >Morinda citrifolia and the order of sensitive species as Nyctanthes arbor-tristis >Bauhinia purpurea> Peltophorum pterocarpum>Psidium guajava> Morinda pubescens. Air pollution tolerance index (APTI) serves as a reliable technique in qualifying plants as tolerant and sensitive species in regard to air pollution. Tolerant species serve as sink of air pollutants and thus can help in abatement of air pollutants to some extent if planted in and around industrial vicinity and along traffic islands.
KEY WORDS: Air pollution tolerance index (APTI), Ascorbic acid content, Leaf-extract pH, Total Chlorophyll Content, Relative Water Content
1. INTRODUCTION- Today the most important topic of global concern is pollution. With rising industrialization and development, an increase in degradation of environment is faced all over the world. Air pollution is one of most fatal of all as we can’t cease the air we breathe. The three main sources of air pollution problem in India are vehicles, industries and domestic sources. As per the guidelines of Ambient air quality monitoring by Central pollution control board,[1] the reasons for high air pollution in India are: poor quality of fuel, poor vehicular design, uncontrolled expansion of vehicle population, old process technology in industries, wrong location of industries, no pollution preventive step in early stage of industrialization, no pollution prevention or control system and poor compliance of standard in small/medium scale industries. 1. INTRODUCTION- Today the most important topic of global concern is pollution. With rising industrialization and development, an increase in degradation of environment is faced all over the world. Air pollution is one of most fatal of all as we can’t cease the air we breathe. The three main sources of air pollution problem in India are vehicles, industries and domestic sources. As per the guidelines of Ambient air quality monitoring by Central pollution control board,[1] the reasons for high air pollution in India are: poor quality of fuel, poor vehicular design, uncontrolled expansion of vehicle population, old process technology in industries, wrong location of industries, no pollution preventive step in early stage of industrialization, no pollution prevention or control system and poor compliance of standard in small/medium scale industries. Air pollution affects the plants as much as it affects humans and animals. On exposure to air borne pollutants, plants experience physiological changes before showing visible damage to leaves [2]. Some plants can thrive in polluted environment and can thus help in cleaning the various sources of manmade pollution both organic (petrochemical) and inorganic (heavy metal toxins) [3]. As part of their regular functioning, trees remove significant amount of pollution from the environment, increasing the air quality and thus should be considered an integral part in aiming overall air quality [4]. The response of plants to pollutants at physiological and biochemical level can be understood by analyzing the factors that determine sensitivity and tolerance.[5] [6] Rao suggested a method where four biochemical parameters such as Ascorbic acid, Total chlorophyll content, Leaf-extract pH and Relative water content were used in determining the resistance and susceptibility of plants to air pollution. Plants with higher APTI value are more accomplished to combat against air pollution and can be used to mitigate pollution, while those with low index value show less tolerance and can be used to signify levels of air pollution. [7] 2. MATERIALS AND METHOD2.1 Study Area: Tarapur industrial area was established in Palghar Taluka of Thane district, Maharashtra by Government of India in 1972. Also known as MIDC Tarapur, it is one of the largest chemical industrial estates of Maharashtra. Tarapur is located 100 km away from Mumbai on western railway track and Boisar is the nearest railway station. It houses many industries like 392 dye industries, 265 textile industries, 138 engineering, 26 iron and steel industries and 1 pesticide industry which are considered as the highly polluting industries by Maharashtra Pollution Control Board [8]. CPCB[9] based on the Comprehensive Environmental Pollution Index (CEPI Index) declared 43 critically polluted areas in India. CEPI Index for Tarapur was 60.75 indicating high pollution levels and hence this area was considered for the experimental study. The location of study site is given in Fig 1.2.2 Sampling of plant species: Fully matured leaves samples were collected from 30 plant species found in this industrial area during two dry seasons i.e. summer and winter (2014). The leaves were brought to laboratory with care, were washed with distilled water to get rid of dust particles and fresh weight was taken immediately. Fresh leaf samples were then analyzed for Ascorbic acid, [10] Leaf-extract pH.[11] Total chlorophyll,[12] and Relative water content. [13] 2.3 Analysis:2.3.1 Ascorbic acid determination: A homogenate was prepared using fresh leaf of the concerned tree species and oxalic acid which was later reacted with 2, 4 –Dinitrophenyl hydrazine reagent along with Sulphuric acid to give an orange red color solution. The absorbance was measured at 540nm. 2.3.2 Leaf-extract pH: 1 gm fresh leaf of the concerned tree species was homogenized using distilled water and pH of the filtrate was detected using digital pH meter. 2.3.3 Total chlorophyll content: Chlorophyll content was analyzed by homogenizing 1gm leaf sample in 20 ml pre-chilled acetone and centrifuging at 5000rpm. The supernatant was later collected and absorbance was measured at 645 and 663nm. 2.3.4 Relative water content: Relative water was calculated by taking fresh weight, dry weight and turgid weight of leaf samples and substituting them in the following formula:RWC = (FW – DW) x 100 (TW– DW)Where, FW- Fresh weight, DW- Dry weight and TW- Turgid weight2.3.5 Air Pollution Tolerance Index (APTI): The values of all the above parameters where then incorporated in the equation as suggested by Singh and Rao [6] and the Air Pollution Tolerance Index for plants was calculated using the formula:APTI = A (T+P) +R 10Where, A =Ascorbic Acid (mg/g), T =Total Chlorophyll (mg/g), P = pH of the leaf extract and R = Relative water content of leaf (%).2.4 Statistical Analysis:Data was analyzed using Correlation and Linear regression analysis between independent variables i.e. ascorbic acid, total chlorophyll, pH, relative water content and dependant variable like A.P.T.I.Fig 1: Location of study site – Tarapur M.I.D.C.Table 1: General description of the plant species considered for APTI studyS.NoPlant species nameFamilySub-familyCommon nameTree type
1Acacia auriculiformis BenthLeguminosaeMimosaceaeAustralian babulEvergreen
2Albizia saman (Jacq.) Merr.LeguminosaeMimosaceaeRain treeDeciduous
3Alstonia scholaris (L.) R. Br.Apocynaceae–SaptaparniEvergreen
4Annona squamosa L.Annonaceae–Custard appleDeciduous
5Artocarpus heterophyllus Lam.Moraceae–JackfruitEvergreen
6Azadirachta indica A. Juss.Meliaceae–NeemEvergreen
7Bauhinia purpurea L.LeguminosaeCaesalpiniaceaeAptaDeciduous
8Butea monosperma (Lam.) Taub.LeguminosaeCaesalpiniaceaePalas, Flame of forestDeciduous
9Cassia fistula L.LeguminosaeCaesalpiniaceaeIndian laburnumDeciduous
10Delonix regia (Boj. ex. Hook.) RafLeguminosaeCaesalpiniaceaeGulmoharDeciduous
11Ficus benghalensis L.Moraceae–BanyanEvergreen
12Ficus hispida L.Moraceae–Benjamin treeEvergreen
13Ficus racemosa L.Moraceae–UmbarEvergreen
14Ficus religiosa L.Moraceae–PipalEvergreen
15Gardenia jasminoides J. EllisRubiaceae–AnantEvergreen
16Gliricidia sepium (Jacq.) Kunth ex Walp.LeguminosaeFabaceaeGiripushpaDeciduous
17Lagerstroemia speciosa (L.) PersLythraceae–TamanDeciduous
18Mangifera indica L.Anacardiaceae–MangoEvergreen
19Morinda citrifolia L.Rubiaceae–NoniEvergreen
20Morinda pubescensJ. E. Sm.Rubiaceae–BartondiEvergreen
21Nyctanthes arbor-tristis L.Oleaceae–ParijatakEvergreen
22Peltophorum pterocarpum (DC.) K.HeyneLeguminosaeCaesalpiniaceaeCopper pod treeEvergreen
23Plumeria obtusa L.Apocynaceae–ChafaEvergreen
24Polyalthia longifolia Sonn.Annonaceae–False AsokaEvergreen
25Pongamia pinnata (L.) PierreLeguminosaeFabaceaeKaranjDeciduous
26Psidium guajava L.Myrtaceae–GuavaEvergreen
27Putranjiva roxburghii Wall.Putranjivaceae–PutranjivaEvergreen
28Senna siamea (Lam.) H.S. Irwin & BarnebyLeguminosaeCaesalpiniaceaeKashidEvergreen
29Syzygium cumini (L.) SkeelsMyrtaceae–JamunEvergreen
30Tamarindus indica L.LeguminosaeCaesalpiniaceaeImliEvergreen
Table 2: Air pollution tolerance index of trees from industrial area of Tarapur(Average of biochemical parameters from summer and winter season± SD) NoPlant species nameAscorbic acid contentTotal chlorophyll content pHRelative water contentAPTI
1Acacia auriculiformis0.64±0.040.39±0.036.44±0.5485.01±1.918.93±0.13
2Albizia saman0.48±0.090.74±0.256.43±0.1367.06±2.347.05±1.16
3Alstonia scholaris0.88±0.250.78±0.025.94±0.0182.11±2.668.80±0.44
4Annona squamosa0.31±0.020.40±0.095.53±0.7273.44±1.007.53±0.07
5Artocarpus heterophyllus0.54±0.090.45±0.116.58±0.0771.72±1.307.55±0.64
6Azadirachta indica1.39±0.020.41±0.056.21±0.1373.56±2.568.27±0.26
7Bauhinia purpurea0.47±0.170.39±0.024.82±2.5766.75±2.006.92±0.82
8Butea monosperma0.64±0.050.42±0.136.42±0.2778.94±1.858.33±0.23
9Cassia fistula1.55±0.050.67±0.026.79±0.4578.50±3.179.00±0.72
10Delonix regia0.21±0.040.40±0.246.83±0.1374.06±2.227.56±1.31
11Ficus benghalensis0.58±0.050.36±0.016.18±0.9187.96±3.219.17±0.21
12Ficus hispida0.49±0.040.55±0.155.75±0.9190.08±3.379.31±0.67
13Ficus racemosa0.97±0.030.37±0.015.55±0.4592.87±3.019.86±0.20
14Ficus religiosa0.51±0.040.69±0.015.88±0.9180.21±0.658.36±0.67
15Gardenia jasminoides0.61±0.060.43±0.476.27±0.1376.17±2.448.02±0.47
16Gliricidia sepium0.91±0.030.33±0.086.23±0.1564.75±1.717.07±1.94
17Lagerstroemia speciosa0.97±0.150.31±0.045.59±0.1371.38±1.607.71±0.85
18Mangifera indica1.49±0.410.51±0.016.47±0.3189.88±1.1710.03±1.44
19Morinda citrifolia1.30±0.010.70±0.166.31±0.0683.53±3.139.26±0.30
20Morinda pubescens1.47±0.560.64±0.065.97±0.6260.32±3.067.00±2.00
21Nyctanthes arbor-tristis0.64±0.060.50±0.046.38±0.0464.25±0.256.87±0.02
22Peltophorum pterocarpum0.33±0.040.70±0.016.29±0.2867.40±3.086.97±0.60
23Plumeria obtusa0.60±0.030.58±0.185.89±0.1483.62±3.138.75±0.53
24Polyalthia longifolia0.20±0.010.42±0.036.68±0.1189.69±1.839.11±0.26
25Pongamia pinnata1.59±0.370.58±0.356.92±0.0880.01±2.999.19±0.27
26Psidium guajava1.56±0.010.30±0.016.45±0.2159.48±2.437.00±0.23
27Putranjiva roxburghii8.35±0.190.53±0.066.25±0.1391.97±2.7014.85±0.45
28Senna siamea0.64±0.310.65±0.065.65±0.2878.55±3.298.26±0.53
29Syzygium cumini0.45±0.090.34±0.156.23±0.1477.95±1.818.09±1.74
30Tamarindus indica0.44±0.010.38±0.013.63±0.0481.64±2.628.34±0.47
Table 3: Correlation between different biochemical parameters and APTI valuesAscorbic acid contentTotal chlorophyll contentpHRelative water contentAPTI
Ascorbic acid content1
Total chlorophyll content0.0751
pH0.1220.1741
Relative water content0.2460.058-0.0301
APTI0.8000.0940.0800.7771
Fig. 2: Linear regression analysis between APTI and Ascorbic acid contentFig. 3: Linear regression analysis between APTI and pHFig.4: Linear regression analysis between APTI and Total chlorophyll contentFig. 5: Linear regression analysis between APTI and relative water contentFig. 6: APTI of plant species from industrial area of Tarapur3. RESULTS AND DISCUSSION- Most of the plant species selected for the study showed higher APTI in winter as compared to summer season. The average value of summer and winter season was evaluated for all the biochemical parameters and then substituted in APTI formula to give an average APTI for all the plant species considered for the study (Table 2, Fig. 6). This helped in identifying the tolerant and sensitive nature of plant species towards pollution. 3.1 Ascorbic acid content: Ascorbic acid showed a weak positive correlation with Total chlorophyll content (r=0.075), pH (r=0.122) and relative water content (r= 0.246) but had a strong positive correlation with APTI (r=0.80) of plant species (Table 3). Putranjiva roxburghii (8.35mg/g) showed high ascorbic acid content while lowest ascorbic acid was seen in Polyalthia longifolia (0.2mg/g) (Table 2). Being a natural antioxidant, Ascorbic acid plays an important role in pollution tolerance by activating many physiological and defense mechanism in plants.[13] According to Garg [14] boost in the level of ascorbic acid content may be due to the resistance mechanism of plant to cope with stress condition since it slows down the leaf senescence. Thus Putranjiva shows tolerance nature to air pollutants while Polyalthia shows sensitive nature.3.2 Leaf-extract pH: A negative correlation (r= -0.030) was seen between pH and relative water content and weak correlation existed between pH and APTI value (r=0.080) (Table: 3). Highest value for pH was seen in Pongamia pinnata (6.92) while lowest pH value was seen in Tamarindus indica (3.63) (Table 2). Agarwal [15] stated that low pH decreases the efficiency of hexose sugar conversion to ascorbic acid and the reducing activity of Ascorbic acid is more at higher pH than at lower pH. Thus high ph can provide tolerance to plants against pollutants. Hence we can say that Pongamia is tolerant species while Tamarindus is sensitive species.3.3 Total chlorophyll content: Total chlorophyll depicted a weak positive correlation with pH (r=0.174), relative water content (r=0.058) and APTI (r=0.094) (Table: 3). Alstonia scholaris (0.78mg/g) showed high total chlorophyll content, thus showing sensitivity to pollution while lowest chlorophyll content was seen in Psidium guajava (0.3mg/g) thus showing tolerance behavior. Joshi [16] concluded in their research that the most important photoreceptor in photosynthesis is Chlorophyll and its measurement is a significant tool to calculate the effects of air pollutants on plants as it plays a crucial role in plant metabolism; any reduction in chlorophyll content directly affects the plant growth. Total chlorophyll content of all the plant samples was less than 1mg/g. Das [17]suggested that high dust accumulation during the winter may be due to wet leave surface with foggy condition and gentle breeze which prevents particle dispersion; and low dust accumulation in summer may be due to high wind speed. Low chlorophyll content during winter season may be due to high dust accumulation on foliar surface of plants inhibiting photosynthesis due to presence of various metals and particles. 3.4 Relative water content: A strong positive correlation (r=0.777) exists between relative water content and APTI of plant species (Table: 3). Ficus glomerata (92.87%) showed high relative water content while lowest was seen in Psidium guajava (59.48%). Relative water content is the water content of leaf which helps in maintaining the physiological balance in plant body under stress conditions induced by air pollution. [18] High Relative water content would mean tolerance to pollutants.3.5 Air pollution tolerance index of plants: By evaluating all the four biochemical parameters in the equation of APTI given by Singh and Rao[17], Air pollution tolerance index of plants was calculated for 30 plants species and is depicted in Table 2. The tolerant plant species were Putranjiva roxburghii, Mangifera indica, Ficus glomerata, Ficus benjamina and Morinda citrifolia while the sensitive species were Nyctanthes arbor-tristis, Peltophorum pterocarpum, Bauhinia purpurea, Psidium guajava and Pithecolobium saman (Fig.6). Regression analysis as shown in Fig. 2, 3, 4 and 5 revealed that Ascorbic acid content and Relative water content were positively correlated with APTI value while Leaf extract pH and total chlorophyll content showed a lesser correlation with APTI of the plant species. This means that both Ascorbic acid content and Relative water content are reliable parameters for checking the susceptibility of plant species.4. CONCLUSION- Air pollution tolerance index (A.P.T.I.) study proves significant in determining the tolerant and sensitive nature of plant species in environment. Higher the A.P.T.I. value more is the tolerance of the plant species and lesser the APTI value, more is the sensitivity of the plant species. Among 30 plant species considered for the experimental study, the order of plants tolerant to air pollution can be stated as Putranjiva roxburghii>Mangifera indica>Ficus racemosa>Ficus hispida>Morinda citrifolia> Pongamia pinnata>Ficus benghalensis> Polyalthia longifolia>Cassia fistula> Acacia auriculiformis. Tolerant plant species can be used in green belt development as they tend to serve as barriers and act as sink for air pollutants. These can thus be planted in and around industrial vicinity and traffic islands to control the level of air pollution. The order of sensitive plant species can be given asNyctanthes arbor-tristis>Bauhinia purpurea> Peltophorum pterocarpum>Psidium guajava> Morinda pubescens> Albizia saman> Gliricidia sepium> Annona squamosa> Artocarpus heterophyllus> Delonix regia. Sensitive plant species on the other hand act as Bioindicators of air pollution and thus can be planted in order to check the environmental health from time to time. High pollution levels can lead to deforestation in long run and thus this kind of study helps in understanding the plants susceptibility and resistance to pollution loads.REFERENCES Central pollution control board (CPCB). “Guidelines for ambient air quality monitoring”. A report by Central pollution control board, Ministry of Environment and Forest, Delhi, 2003.Dohmen GP, Koppers A and Langebartels C.Biochemical response of Norway spruce (Picea abies (L.) Karst.) towards 14-month exposure to ozone and acid mist: effects on amino acid, glutathione and polyamine titers. Environmental Pollution, 1990; 64:375-383.Thambavani SD and Sabitha MA. Variation in air pollution tolerance index and anticipated performance index of plants near a sugar factory: implications for landscape-plant species selection for industrial areas. Journal of research in Biology, 2011; 7: 494-502.Abida B and Ramaiah H .M. Evaluation of some tree species to absorb air pollutants in three industrial locations of South Bengaluru, India. E-Journals of Chemistry, 2010; 7(S1):S151-S156. Suvarna lakshmi P, Lalitha Sravanti K and Srinivas N. Air pollution tolerance index of various plant species growing in industrial areas. The Ecoscan, 2008; 2 (2): 203 – 206.Singh S K and Rao D N. Evaluation of plants for their tolerance to air pollution.” In: Proceedings Symposium on Air Pollution Control, (Indian Association for Air Pollution Control, New Delhi, India) 1983;1:218-224.Joshi N and Bora M. Impact of air quality on physiological attributes of certain plants:Report and Opinion, 2011;3(2):42-47.Maharashtra Pollution Control Board (MPCB). Action plan for Tarapur industrial area, 2010.http://mpcb.gov.in/CEPI/pdf/Action%20Plan%20CEPI-Tarapur.pdf.Central Pollution Control Board (CPCB). “Current air quality issues in India”, a paper presented by Central Pollution Control Board, Ministry of Environment and Forests, Delhi, 2011.Sadasivam S. and Manickam A. Biochemical methods. 2nd ed., New Delhi; New Age International Pvt. Ltd. Publishers: 2009: pp. 284.Arnon DI.Copper enzyme in isolated chloroplasts. Polyphenol oxidase in Beta vulgaris. Plant Physiol., 1949; 24:1-15.Weatherly PE. Examination of the relative turgidity technique for estimating water deficit in leaves. J. Biol. Sci., 1965; 15: 413-428. Chen YM, Lucas PW and Wellburn AR. Relative relationship between foliar injury and change in antioxidants levels in red and Norway spruce exposed to acidic mists. Environmental Pollution, 1990; 69(10): 1-15.Garg OP and Kapoor V. Retardation on leaf senescence by ascorbic acid. Journal of Experimental Botany, 1972; 23: 699-703.Agarwal A L. Air pollution control studies and impact assessment of stack and fugitive emission from CCI Akaltara cement factory, project sponsored by M/S CCI Akaltara cement factory, NEERI, Nagpur,1988.Joshi PC and Swami A. Air pollution induced changes in the photosynthetic pigments of selected plant species. Journal of Environmental Biology, 2009; 30(2): 295-298.Das S and Prasad P. Seasonal variation in air pollution tolerance indices and selection of plant species for industrial area of Rourkela. Indian J. of Env. Protection, 2010; 30(12): 978-988.Dedio W. Water relation in wheat leaves as screening test for drought resistance. Canadian J. Plant Sci., 1975; 55:369-378.